Mean Well PB-1000 User Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 14
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
3
Pin No. Function
Description
3,4
5,6
9,10
7,8
RY14
RY15
RC-/RC+
GND/RTH
Rela y contact rating (max.): 30V/1A. "Short" when bank B is full.
Re lay contact ra ting (max.): 30V/1A. "Short" when the unit is working
Turn the output ON and OFF by electrical or dr y contact between
Temperature sensor which comes with the charger ca n be connected
"Open" when bank B is still cha rging.
prope rly. "Open" when the unit has faile d or protect io n has a ctivated.
pin10 (RC+) and pin9 (RC-). Open: start charging. Short: stop charging.
to the unit to allow temperature compensation of the charging voltage.
If the temperature sen sor is not used, the charge r ca n still w ork
norma lly.
5.LED In dication
6.Explanation of operation logic (charg ing stages):
PB - 1000 has a tota l of 3 ch arging modes to choose from, 2 s tag es, 3 stages, and
8 stages. 8 stages charging differ from 2 stages with the addition of pulse, soft start,
analysis, recondition, float, and maintain stages. 2 stages provide simple and quick
charging. 3 stages is sim ilar to 2 stages with the exception of not shutting OFF after
the battery is fully charged. Lastly, 8 stages will allow charging to maximum capacity.
User can select between 2,3 or 8 stages depend ing on their requirement.
6.1 2 s tage charging (flick switch to "2" stage)
PB-1000 has ch annels A & B which can p erform 2 stages charging individually.
Channel A will be the first to commence charging. During initial charge (stage 1),
charger will provide maximum current to the battery. The built-in fan will also tur n
ON. As the batt ery s tart s to get full, cha rgin g cu rren t will gra dually decre ase
(stage 2). When charging current decrease to less than 10% of max. LED indicator
wil l t ur n Gr een t o s how a f u ll charge . C h ann el A wil l turn OF F w hile cha rgin g
commence at Channel B. After the battery at channel B is fully charged, PB-1000
will turn OFF its outputs.
Start
B ank A
C onstant
C ur rent
Bank B
Cons tant
Curre nt
Bank A
Consta nt
Voltage
Bank B
Constant
Volt age
Bank A
Charging
Ends
Bank B
Charging
Ends
Types of failure:
1
5
2 3
4
Battery disconnected
Activation of protection function (e.g. OTP, OVP, and Short)
Damaged battery Reverse polari ty
Incorrect battery voltage (e.g. PB-1000-12 connected to 24V battery)
Status
Color
Red
Orange
Green
Steady
Fail
Full Charging
Charging
Flashing
Page view 4